Product Overview
A hospital elevator is judged by what it can move without disturbing the person being moved. If a project needs passenger or goods lifts as well, this hospital lift can be ordered in the same package from the same factory, with one set of drawings for the whole building. Most orders come from elevator sales and service companies and elevator constructors configuring equipment for a healthcare client: one configuration to quote, drawings that match the shaft, and a technical contact who answers while the tender is still open.
Cabin Layout & Patient Handling
- Floor space that goes to the patient. The car frame is optimized for clinical use, so the clear area is spent on the bed, the trolley and the two or three people steering them rather than on trim.
- Stainless steel interior. Cabin surfaces are stainless steel, as shown, so the car can be wiped down between transfers and takes trolley knocks through a full shift.
- A handrail at standing height. A continuous wall handrail gives walking patients and staff something to hold, and shields the wall from trolley corners.
- Layout drawn around the real bed. A hospital lift is only as useful as its door opening: send the length, width and height of the beds and stretchers you handle, and the lift manufacturer dimensions the car and entrance around the largest item.
- Sliding doors. Doors slide rather than swing, so the entrance stays clear while a bed is lined up at an angle in a busy corridor.
- Even ceiling lighting. Light panels in the cabin ceiling keep the patient's colour, drip lines and monitor screens readable during a short transfer.
- A landing a trolley can roll across. Speed regulation lets the car settle at the floor without a jolt, so castors do not catch on the sill as the bed is pushed in.
Smooth Ride & Speed Control
A patient moving between a ward and a theatre is usually on a trolley, sometimes with lines and monitors attached, and always with staff walking beside it. The speed control on this series is tuned for accuracy and calm rather than outright pace: the car accelerates progressively, runs at a steady rate and eases to a stop at the floor.
Three rated speeds are offered, and each keeps the same regulated profile, so a taller building does not mean a harsher ride. The higher ratings mainly cut waiting time on long travels and help a bank of cars keep pace with demand between floors.
What the building gets is predictability: the same gentle start and stop on every trip, a trolley that stays where it was put, and staff who know how the car will behave with a patient inside. For hospital lifts for patients who cannot be tilted or jolted, that counts for more than the top figure on the datasheet.
Hospital Lift Applications
- Ward blocks and bed towers. Beds move between wards, diagnostics and theatre floors, usually with two or three staff walking alongside the car.
- Emergency and admission areas. Stretcher traffic arrives in bursts, and dedicated hospital lifts for patients keep those transfers out of the public passenger cars.
- Theatre and recovery floors. Equipment trolleys, anaesthetic machines and post-operative beds share the same shaft, often at short notice.
- Outpatient and day-surgery clinics. Trolleys and wheelchair users ride with walking patients, so the layout has to work for both.
- Nursing homes and care facilities. Residents with frames and wheelchairs, smaller staff teams and short journeys; elevator lifts at the lighter end of the load range are usually well-suited to these buildings.
- Polyclinics and medical office buildings. A steady mix of patients, staff and supplies rather than emergency traffic, so elevator suppliers usually specify a hospital elevator here that keeps the building moving without oversizing the shaft.
Capacity & Travel Configuration
| Specification | Value |
|---|
| Rated speed | 1.0 / 1.5 / 1.75 m/s |
| Rated load capacity | 1350 / 1600 / 2000 kg at every rated speed |
| Maximum travel height | 60 m at 1.0 m/s; 80 m at 1.5 m/s; 90 m at 1.75 m/s |
| Maximum number of floors | 16 at 1.0 m/s; 24 at 1.5 m/s; 28 at 1.75 m/s |
| Speed regulation | Accurate, smooth control of start, run and stop |
| Door operation | Sliding car and landing doors |
| Cabin layout | Humanized design with an optimized car frame |
| Typical buildings | Hospitals, clinics, nursing homes, care facilities |
Load Rating Selection
- Start with what actually rides in the car. Weigh the bed or stretcher, the patient, the mattress and the monitors or infusion stands that travel with them, then add the staff walking alongside. The total, taken up to the nearest rating in the series, is the figure to quote — an average patient weight tells you nothing useful.
- 1350 kg suits stretcher-led routes. This is the rating for clinics, day-surgery units and care homes, where the heaviest item is a stretcher with a working margin around it rather than a full ICU bed, and where equipment moves on separate trolleys.
- 1600 kg is the usual ward-block choice. A full bed, staff on both sides and the monitor stand or equipment trolley that always travels with it — most multi-ward hospital lift specifications settle here once the escort is counted.
- 2000 kg covers occupied ICU beds and equipment-heavy routes. Ventilation, monitoring and infusion equipment attached to the bed, the transfer team, and any route where a bed and a heavy trolley have to ride together.
- The rating reaches further than the cabin. A heavier car means a larger car frame, heavier guide rails, a bigger traction machine and more load carried into the machine beam or slab, so the shaft, pit and overhead must be checked against the chosen rating before the layout drawing is frozen.
- Load and speed are separate choices. All three ratings run at 1.0, 1.5 and 1.75 m/s, so a tall building does not force a heavier car and a heavy car does not force a slower one; set the load from the equipment and the speed from the travel and stop count.
- Under-rating is the costly direction. Over-rating spends steel, shaft space and machine size the building never gets back; under-rating surfaces after the drawing is approved, when the car, the rails and often the shaft have to be reworked. Fix the number at tender stage, with the hospital's clinical team and the structural engineer in the same conversation.
- Record the equipment list on the drawing. Note the beds, incubators and trolleys that will use the hospital elevator in the approved layout, so a later change in equipment is a documented decision rather than a surprise on site. If the project is still at bid stage, send us that list and we will confirm the rating against it before an elevator contractor prices the package.
Configuring to Your Shaft
| Item | What to send |
|---|
| Shaft width and depth | Clear internal dimensions measured at each floor |
| Pit depth | Finished floor level down to the base of the pit |
| Overhead | Top floor level to the underside of the slab or machine room |
| Travel and stops | Floor-to-floor heights, total travel and number of stops |
| Door opening | Clear width and height needed for the bed or trolley in use |
| Rated load | The heaviest bed, trolley and equipment combination on the route |
| Rated speed | Travel, stop count and the traffic the lift has to keep up with |
| Entrance positions | Which side each landing door sits on |
Ordering & Delivery
- Tell us about the building — the shaft you have, the floors it serves and the equipment your client moves — and we will confirm what else is needed to complete the configuration.
- As the lift manufacturer we prepare the layout drawing and configuration for approval: car size, door opening and entrance positions agreed against the shaft.
- Confirm the certificate and test documents the tender requires so the right package travels with your order; this is the paperwork an elevator contractor hands over at completion.
- Delivery schedule, packing and shipping terms are agreed per project — elevator suppliers quoting a hospital package should confirm current lead time and terms with their sales contact before the tender goes in.
- Units ship packed for sea freight, and elevator lifts of this size are crated for container loading; check the packing list against your site's unloading and storage arrangements before the container arrives.
- Your own crew or a local elevator contractor erects and commissions the lift with our drawings and technical guidance, and we stay reachable while the work is on site.
- After handover, spare parts and service support run through the same contact.
Scale & Supply Capability
WELLS Elevator is a Sino-German cooperation enterprise and High-Tech manufacturer, founded in 2005 and operating from Shanghai and Kunshan with a team of 65 people. We handle R&D, design and manufacturing in-house, and supply the categories that make up a complete vertical-transport package, so buyers can source a whole project from one supplier. Over 30 models hold CE certification from TUV and other European institutes, and our quality management is ISO9001 certified. We support OEM and customized builds, and have delivered projects in more than 40 countries, with technical support throughout.
Specification
WELLS hospital elevator pays attention to humanized design, optimize the cabin frame, and suffice passengers' needs. The serie has been building a space not only for transporting passenger but also for supporting heavy load capacity and demands by controlling the running speed accurately and placidly.
| Rated Speed (m/s) |
Load Capacity (kg) |
Max. Traveling Height (m) |
Max. Floors |
| 1.0 |
1350 |
1600 |
2000 |
60 |
16 |
| 1.5 |
1350 |
1600 |
2000 |
80 |
24 |
| 1.75 |
1350 |
1600 |
2000 |
90 |
28 |
FAQ
How does a hospital elevator differ from a standard passenger lift?
The duty is different, so the specification is different. A passenger car is sized for people standing and walking a short distance; this one is sized around a bed or stretcher with staff walking beside it, and the control profile is tuned for a gentler start and stop. The cabin also carries what clinical work needs — a continuous handrail, stainless steel surfaces and even ceiling light — instead of decorative finishes.
Can the car carry a bed and a stretcher at the same time?
No. Hospital lifts for patients are sized around the largest single item the building moves, plus the team escorting it: either a bed with attendants on both sides or a stretcher with more free floor around it. Send the length, width and height of your beds and trolleys and the car and door opening are drawn around that item.
Which rated load should we specify: 1350, 1600 or 2000 kg?
1350 kg covers stretcher traffic and smaller beds in clinics and care homes. 1600 kg suits general ward blocks, where a bed travels with staff, a trolley and equipment alongside. 2000 kg is for intensive care transfers and equipment-heavy routes. Tell us the heaviest bed and trolley combination on the route and we will confirm the rating — elevator suppliers preparing a tender usually fix this early, because it drives the shaft size.
Is the cabin easy to clean between patients?
The cabin surfaces on these elevator lifts are stainless steel with a continuous wall handrail, so there are no fabric panels or deep trims to hold soil. Both wipe down with the disinfectants hospital cleaning teams already use. The fittings supplied with your order are listed on the approval drawing, which is the sheet to hand to the cleaning supervisor.
Can the same model serve a nursing home or a clinic?
Yes. The series is built for hospital and nursing-home environments, and hospital lifts for patients in care settings usually sit at the lighter end of the load range, where residents move with frames and wheelchairs and journeys are short. The cabin layout stays the same — handrail, stainless surfaces, clear floor area — so a care home gets the same handling without paying for capacity it will never use.